Update the SEGGER toolchain or forcefully purge the underlying .inf file.
jlink is a tool that comes with the JDK. It was introduced in Java 9 as part of JEP 332 (Java Runtime Packaging Tool). The primary purpose of jlink is to create a runtime image of a Java application. A runtime image is a complete directory that contains everything needed to run a Java application, including the Java runtime environment (JRE), application classes, and application resources.
Download the latest version of the . Run the installer and follow the on-screen instructions. jlinkx64sys
If Windows Security flags jlinkx64.sys as an incompatible driver, you can resolve the issue using one of three methods: Updating, Forcefully Uninstalling, or Using Third-Party Cleaners. Method 1: Update to the Latest SEGGER Drivers (Recommended)
If you did not intentionally install J-Link software, run a full scan with Windows Defender and a secondary scanner like Malwarebytes or HitmanPro to remove the potential infection. Update the SEGGER toolchain or forcefully purge the
Many Windows 11 users encounter this file through a critical security warning from . When trying to toggle on Memory Integrity (also known as Hypervisor-protected Code Integrity, or HVCI), the system blocks the action and flags jlinkx64.sys as an incompatible driver.
The file is a critical software component associated with SEGGER Microcontroller systems . Specifically, it serves as the 64-bit USB Bulk Driver used to enable communication between a host computer and SEGGER J-Link debug probes . These hardware probes are the industry standard for programming and debugging embedded microcontrollers across various architectures, such as ARM, RISC-V, and MIPS. The primary purpose of jlink is to create
Modern Windows x64 systems require all kernel drivers (like JLinkx64.sys ) to have a valid digital signature.
Reboot your PC. Memory Integrity will now turn on without issue. Summary Matrix SEGGER Microcontroller GmbH Safe Component? Yes, it is non-malicious hardware utility software. Common Issue Blocks Windows 11 Memory Integrity / Core Isolation. Primary Fix
Use the J-Link Configurator utility included with the Segger software suite. It can detect if the device is using the wrong driver and "Convert" it back to the official Segger driver. 3. Security and Virtualization Issues
Understanding and Fixing the jlinkx64.sys Blue Screen Error If you are a developer, embedded engineer, or use specialized USB debugging hardware, you might encounter a on Windows 10 or 11 with the error file jlinkx64.sys . This driver is often the root cause of unexpected system shutdowns and crashes when working with SEGGER J-Link debugging probes.
| Current | USB: normal 30 mA; Suspend mode 300 uA RS-232: Quiescent 1-2 mA typical (continuous), transmitting 8-9 typical (5ms duration), peak at power on 12 mA |
| USB & RS-232 Size |
Length: 3.94” (100.0mm) Width: 1.28” (32.5mm) Height: 1.23” (31.3mm) |
| USB & RS-232 Weight |
Weight: 4.5 oz. (127.57 g) |
| TTL 100 mm Size |
Length: 3.94" (100 mm) Height: 1.23" (31.3mm) Width: 1.28" (32.5mm) |
| TTL 101 mm Size |
Length: 4.0" (101.6 mm) Height: 1.08" (27.4 mm) Width: 1.62" (41.1 mm) |
| Temperature | |
| Operating | -30 °C to 70 °C (-22 °F to 158 °F) |
| Storage | -40 °C to 70 °C (-40 °F to 158 °F) |
| Humdity | |
| Operating | 10% to 90% noncondensing |
| Storage | 10% to 90% noncondensing |
| Altitude | |
| Operating | 0-10,000 ft. (0-3048 m.) |
| Storage | 0-50,000 ft. (0-15240 m.) |